Seismic
Recording Parameters:
The
seismic data were recorded by ESRI-University
of South Carolina between March 19 and March
26, 1999. A total of four profiles were
acquired designated lines Z-9-1, Z-9-2,
Z-9-3, and Z-9-4.
|

|

|
|
(Moving
seismic cable in 200 West Area)
|
(Buried
'rads' posed a logistical
complication)
|
|
Type
of Survey
|
P-wave
seismic reflection
|
|
Station
Interval
|
1
meter
|
|
Source
|
Industrial
Vehicles International (IVI) MiniVib
high-frequency vibrator 12,000 lb.
peak force
|
|
Source
Interval
|
1
meter on half stations
|
|
Type
of Sweep
|
Linear
|
|
Sweep
Frequencies
|
30
– 300 Hz
|
|
Sweep
Taper
|
Start
= 0.35 s, End = 0.1 s
|
|
Sweep
Length
|
6 s
|
|
Source
Offset (Pad)
|
1.5
meters nominal
|
|
Record
Length
|
7 s
|
|
Listen
Time
|
1 s
(7 s RL – 6 s Sweep)
|
|
Recording
Instrument
|
Geometrics
StrataView RX 24 bit A/D resolution
|
|
Number
of Recording Channels
|
120
|
|
Instrument
Gain
|
48
db fixed
|
|
Field
Correlator
|
none
|
|
Sample
Interval
|
0.5
ms
|
|
Data
Format
|
SEG-2
|
|
Data
Redundancy (CDP fold)
|
60
|
|
Geophones
|
Geospace
40 Hz vertical 3 per station bunched
and buried
|
|
Cable
Geometry
|
40.5m--0.5m--VP--0.5m--78.5m
|
|