Seismic Recording Parameters:

The seismic data were recorded by students and staff of ESRI-University of South Carolina. After acquisition and processing of line M-1, the recording parameters were modified for acquisition of lines M-2 & M-3.

(Sledge hammer seismic source)

(Three geophones bunched per station)

Recording Parameters:

 
Type of Survey P-wave seismic reflection
Station Interval 2 ft
Source Sledge hammer, 8 hits/Sp
Source Interval 2 ft
Record Length 500 ms
Recording Instrument Oyo DAS-1 24 bit A/D resolution
Number of Recording Channels 48 M-1, 96 M-2 & M-3
Instrument Gain 48 db fixed
Sample Interval 0.25 ms M-1, 0.50 ms M-2 & M-3
Data Format SEG-2
Data Redundancy (CDP fold) 24 M-1, 48 M-2 & M-3
Geophones Geospace 40 Hz vertical 3 per station bunched
Cable Geometry

SP---20'-----114' M-1

SP---29'-----219' M-2 & M-3